Blood Collection Tubes

TransFix/EDTA Vacuum Blood Collection Tubes (TVTs) are plastic, direct draw collection tubes used to stabilise venous blood at the point of collection and preserve whole blood specimens for immunophenotyping by flow cytometry. TVTs are prefilled with sufficient TransFix containing K3EDTA for the immediate anticoagulation and stabilisation of 3 mL or 9 mL of blood for up to 14 days.

All TVT are CE marked for IVD use in Europe and 3 mL versions are available for IVD use in the USA. 

Contact us about this product

Sample Storage Tubes

Features of TVTs

  • Preserve the cell surface antigens of lymphocyte subsets for up to 14 days.
  • Prefilled with sufficient TransFix and K3EDTA to stabilise and anticoagulate a final draw volume of 3 mL or 9 mL of blood.
  • Multiple pack sizes available.
  • Immediate stabilisation providing optimal sample stability.
  • Ease of application: TransFix/EDTA Vacuum Blood Collection Tubes fit docking sheaths from most manufacturers.
  • Sterilised by gamma radiation.

Benefits of TVTs

  • Reduced variability:
    • Ensures sample integrity during transportation between testing sites.
    • Reduction in pre-analysis variability – all samples preserved at the same time point.
    • Reduces the impact of unexpected delays in analysis
  • Convenience:
    • Easy to use – directly collect blood into TransFix then just mix by inversion.
    • Minimal “hands-on” time at collection sites
  • Reduced cost:
    • Greater efficiency in testing – allows for batching of samples prior to testing.
    • Prevent the need for repeat phlebotomy due to degraded samples.
    • Further tests can be performed on the same sample after the initial analysis, without subject recall.

Product Codes

TVT-03-1 TransFix/EDTA 3 mL Vacuum Blood Collection Tubes (1 tube)
TVT-03-2 TransFix/EDTA 3 mL Vacuum Blood Collection Tubes (2 tubes)
TVT-03-50 TransFix/EDTA 3 mL Vacuum Blood Collection Tubes (50 tubes)
TVT-09-1 TransFix/EDTA 9 mL Vacuum Blood Collection Tubes (1 tube)
TVT-09-2 TransFix/EDTA 9 mL Vacuum Blood Collection Tubes (2 tubes)
TVT-09-50 TransFix/EDTA 9 mL Vacuum Blood Collection Tubes (50 tubes)

TVT Related Articles

TransFix Compatible Antibodies

TransFix is designed to stabilise TBNK surface markers for up to 14 days for flow cytometry analysis.  Researchers around the ...

Preservation of CD34+ Stem Cells and Precursors with TransFix

CD34+ population enumeration has multiple applications, for example to indicate whether a hematopoietic stem-cell harvest is ready to be performed ...

New Research demonstrates the benefits of TransFix®/EDTA Vacuum Blood Collection Tubes

A new paper published in Cytometry part B, compares two blood stabilising products: the TransFix®/EDTA Vacuum Blood Collection Tube (TVT), ...

Stabilisation of T-Cell Activation Markers

Measurement of T-cell activation can be important when assessing immune responses, however cells can become artificially activated over time once ...

TVT Resources

Reset
  • Brochures and Flyers

  • Cytomark Brochure 2024

  • TransFix®: A Cellular Antigen Stabilisation Reagent

  • TVT Flyer - CE IVD

  • Posters

  • Freezing Blood Samples for Deferred Immunophenotyping

  • Inter-laboratory Comparison of the TransFix/EDTA Vacuum Blood Collection Tube (TVT) with the 5 mL Cyto-Chex® BCT

  • Instructions

  • TransFix®/EDTA Vacuum Blood Collection Tubes - Instructions For Use (RUO)

  • TransFix®/EDTA Vacuum Blood Collection Tubes - Instructions For Use (CE/IVD)

  • Symbols Glossary

  • Further Information

  • ISO 13485:2016 Certificate

  • Antibodies compatible for use with TransFix

  • Bibliography

  • WHITE PAPER: Freezing Blood Samples for Deferred Immunophenotyping

    This study used the TVTs and BCTs to compare the immunophenotype of fixed peripheral whole blood samples at time zero, and after freezing at -80°C for 7 days. The structural integrity of the frozen TVTs and BCTs were also examined. Optimisation of storage conditions was further investigated to improve immunophenotyping after freezing. TVTs showed the best cell percentage differences from the control with average lymphocyte cell recovery of 77% compared to 26% for the BCTs. All three BCTs cracked during the freezing process while all of the TVTs remained intact. Storage optimisation experiments showed tubes frozen at an angle and thawed at 37°C performed best overall. These results raise the possibility that whole blood samples for immunophenotyping may be stored at -80°C for extended periods beyond 7 days. Further studies will aim to demonstrate the upper limit of time the sample will remain stable and suitable for immunophenotyping. Experiments will also be conducted to examine the suitability for use in phosphoflow assays.
    D. Coupar, J. Thompson, N.Kaenzig | 2019 | Cytomark White Paper
  • Material Safety Data Sheets

  • TransFix Veiligheidsinformatieblad (Nederlands)

  • Transfix Sikkerhetsdatablad (Norsk)

  • TransFix Sikkerhedsdatablad (Dansk)

  • TransFix Sicherheitsdatenblatt (Deutsche)

  • TransFix Scheda di Dati di Sicurezza (Italiano)

  • TransFix Säkerhetsdatablad (Svenska)

  • TransFix Material Safety Data Sheet (English)

  • TransFix Material Safety Data Sheet (English - US)

  • TransFix Fiche de données de sécurité (Français)

  • TransFix Fichas de datos de seguridad (Español)

  • Transfix Ficha de dados de segurança (Portuguesa)

  • TransFix Bezpecnostni list (Czech)

  • Certificates of Analysis/Conformity/Conformity

  • Batch 30062 (RUO)

  • Batch 30062 (CE/IVD)

  • Batch 30056 (RUO)

  • Batch 30054 (RUO)

  • Batch 30054 (CE/IVD)

  • Batch 30053 (RUO)

  • Batch 30053 (CE/IVD)

  • Batch 30046 (CE/IVD)

  • Batch 30037 (CE/IVD)

  • Batch 30030 (RUO)

  • Batch 30029 (RUO)

  • Batch 30029 (CE/IVD)

  • Batch 30025 (CE/IVD)

  • Batch 30005 (CE/IVD)

  • Batch 30005 (CE/IVD)

  • Batch 30002 (RUO)

  • Batch 30001 (CE/IVD)

  • Batch 29991 (CE/IVD)

  • Batch 29990 (CE/IVD)

  • Batch 29980 (IVD)

  • Batch 29957 (RUO)

  • Batch 29957 (IVD)


Explore All Resources